Everybody is good, the first post, beginner vc + + and 1553 b bus, the teacher gave a test equipment to do now BC write test software, data receiving RT equipment, collection, storage, display, software written now is the use of 1553 b interface card provider to routines that have "open threads" a compiled code to pass, but blocking open threads that directly put the BC receive function to start code, the generated software click start software directly after the crash, which master to send a routine or on-site play a down some writing code or hint, RT report data for 15 of the 16 bit unsigned integer, the younger brother in this first thank you master,

CodePudding user response:

Why nobody reply

CodePudding user response:

Also to write data acquisition, encouragement, come on,

CodePudding user response:

Not play a 1553 b, many years BC to initialize can be used, each have the drive and interface, certainly not universal

CodePudding user response:

Thank you, problem almost solved

CodePudding user response:

Might as well use CxSerial serial
http://www.cnblogs.com/EdmundDwyane/p/3174308.html

CodePudding user response:

Hello the building Lord, I have also recently in about 1553 b bus, I want to ask you know not to know Condor PCI - 1553 series interface card after I installed the driver how to realize his MT function, need their PC software BusTool VC set or I direct call DLL generated inside the corresponding API function is ok,, thank you very much!

CodePudding user response:

refer to the original poster shuimiaobian response:
everybody is good, the first post, beginner vc + + and 1553 b bus, the teacher gave a test equipment to do BC now write test software, data receiving RT equipment, collection, storage, display, software written now is the use of 1553 b interface card provider to routines that have "open threads" a compiled code to pass, but blocking open threads that directly put the BC receive function to start code, the generated software click start software directly after the crash, which master to send a routine or on-site play a down some writing code or hint, RT report data for 15 of the 16 bit unsigned integer, the younger brother in this first thank you master,


Hello the building Lord, I have also recently in about 1553 b bus, I want to ask you know not to know Condor PCI - 1553 series interface card after I installed the driver how to realize his MT function, need their PC software BusTool VC set or I direct call DLL generated inside the corresponding API function is ok,, thank you very much!