Home > other >  Of new help everyone dalao, mitsubishi FX3U how to implement equipment dormant after the original ge
Of new help everyone dalao, mitsubishi FX3U how to implement equipment dormant after the original ge

Time:05-12

PLC devices are FX3U 48 Mr

IO is X0 button button 1 2 X1 button 3 X2 stop X3 reset button 5 4 X4 scram 7 x 5

Low-grade Y1 Y2 midrange high-end Y3 green Y10 white light Y11 red Y12 buzzer Y13 eye light sensor Y14

This topic request is

Is black the underlined part I difficult to complete part of the

Equipment are not start when the red light normally on

Press 1 button, the green led flashes 2 seconds, buzzer sounds at the same time, the corresponding relay connected, at this time for the low speed running state, normal running normally on the green lights, buzzer closed, frequency converter according to the low frequency operation,

Press the button, the 2 green lights flashing 4 seconds buzzer sounds at the same time, the corresponding relay connected, at this time for medium speed running state, normal running normally on the green lights, buzzer closed, frequency converter according to the medium speed speed run,

Press 1 button, the green light flashing 6 seconds buzzer sounds at the same time, the corresponding relay connected, at this time for high speed running state, normal running normally on the green lights, buzzer closed, frequency converter according to the high frequency operation, note: item (1, 2, 3 must interlock)

Press the stop button, 4 stop running state, running lights put out, without any moving

when equipment in normal operation, the light sensor) blocked in packages, normally on the white light, buzzer rang, must press the reset button on 5th, at this time no need to press the start button equipment may continue to run according to the previous way, but it must be in accordance with the requirements of the three kinds of speed continues to run,

When light eye no goods within 10 seconds of sensor through the equipment in a dormant state, in a dormant state when we have the goods through without having to press the start button, equipment automatically according to the selected speed up before start,.

When press the stop button and 7, all actions to stop, normally on red lights, buzzer rang, want to run again, need to press the reset button and then press the start button can normal boot,,

  • Related