Unconventional 485 system fault for help
Time:09-16
Has always been a half a bucket of water technician, for many years, frequent transition reasons, what have learned a little, what all don't proficient, , in recent years the company has a walk the modbus network system of dc motor, is 485 through the network to control dc motor actually do some simple forward reverse action, at the same time some state feedback, Structural design of a floor there is a project, as shown in figure, each floor in the two groups 485, construction of north and south side, about 30 meters, the farthest distance rate of 485 to 9600, Known issue: the project is made of early, according to the development of this system was half a bucket of water, the guidance of the Hong Kong guy think distance is short, node and less, so don't go doing very heart 1, network topology, no strict holding hands, a city's bus is probably more than 20 meters, about four or five meters, each branch line and individual nodes because access port changed position increases the distance, 2, power with the three, two of the same brand and specifications about 27.9 V, a different brand different specifications about 26 V, 0 V lower than the other two power supply is also about 2 V,
In recent years is in the graph on the right side of the equipment (single power supply) has always been very normal, there is almost no miss, often the problem can't unicom on the left side of the equipment, even after the resumption of normal soon began to trouble,
Before the user use very little also calculate, have recently begun to use frequently, fault become can't avoid, under the guidance of the Hong Kong guy, doubt power problem these days made several lines, 1, the original device on the electricity, there is a 3 and a half hours after the error and hot near the 485 chip, another up, the beginning is normal, but it didn't take long and the same situation, 2, the three power of 0 v and connect together, the results lost in large area, failure, 3, taking down the 26 V the power source, its original take on four groups of power by the other two 27.9 V power supply share, at first the original normal 8-14 completely lost, after and 0 V is normal, but 6 or make a mistake, it didn't take long 1, 4 error, failure, 3, keep the 26 v power supply, originally a Shared by two other power supply power supply on the four groups of one of the power supply, there is a 6 errors, still observe the follow-up situation, As shown,
Thank you for your guidance for sure,
CodePudding user response:
1, hot chip, check each terminal have resistance, only as far as a terminal resistance line, 2, check for leakage, 3, the merger of 0 v should not have too big effect, check the specific circuit of voltage,