Motor is the negative current problems
Time:09-30
Permanent magnet synchronous motor and controller is installed on the electric dynamometer bench test, bench motor speed control, measured motor three-phase PWM duty ratio was 50%, all the negative current, the higher the speed, the greater the current, what a great god can explain the reason
CodePudding user response:
The negative current is bus current or a phase current? So-called current is negative, it is a reference to the volatility, volatility, may be your abnormal part of the interference and power supply, power supply work abnormal reason, generally cut right or not for you, the efficiency is low, lead to electrical power did not translate into mechanical power, cut correctly or not may be the cause of cutting phase voltage point is wrong, you also may be the result of your degaussing didn't have enough time to cut phase voltage point wrong,
CodePudding user response:
Three-phase PWM duty cycle is fixed value 50%, at this point I control algorithm is not running, motor torque output, in my understanding, the motor being dragged, there should be no current, but to me is a phase current, bus current is negative, the test when another set of motor controller, no current, that is why?
CodePudding user response:
Duty is higher than 50% remain unchanged, electricity at ordinary times all three phase line to the busbar is, relative to the three-phase motor is received on the same point, at this time can be as a three phase short circuit, when the motor is drag in power state, the three phase line will be a counter electromotive force is the voltage, the motor phase line is in short circuit condition, nature has the current phase line,
CodePudding user response:
Bridge arm under 50% of the time not half time is fully open, half open time is on the bridge arm, its valid values should not be zero?