Want to take advantage of the electromagnetic valve of the open and shut off the flow of control (proportional valve price is a little high, the company to control costs, don't want to use,)
Anyway I want to control on-off solenoid valve, is a high speed on-off, switching frequency is around 50-80 times in the 1 s (optional solenoid valve is support, can reach 100 times), I met the question is: now I can't circuit control electromagnetic valve action, can't open, I use the PWM wave to control triode, in turn, control the switch of MOS tube, for electromagnetic valve power supply and power outages, circuit is as follows:
I have some questions so: (1) general solenoid valve (power for work, this will not work, no special support PWM wave to control electromagnetic valve) can have a PWM wave to control quickly opened and shut off? (2) whether there is something wrong with my circuit design, resulting in PWM control solenoid valve (opened)? (3) their access to some data, it was said the size of the PWM wave will eventually be converted into current, my current is too small to open the solenoid valve, oneself also know for motor speed control PWM wave, so that transformed the average high and low voltage, thus realize the fast and slow, (4) there is a phenomenon is: I board connection solenoid valve, with electricity, electromagnetic valve have no reaction, waveform oscilloscope for testing, no PWM wave output, electricity before take off solenoid valve test waveform is OK, this way the new burning program measurement and waveform, didn't understand why? (5) have the experience of friends, can you provide a train of thought, or drive circuit?
CodePudding user response:
Such high switch frequency serious affecting the service life of solenoid valve, the noise is also a big problem, or an alternate plan early,
CodePudding user response:
Principle of the circuit itself is no problem, to see whether the electromagnetic valve drive parameters (voltage, current, start time, closing time, delay, etc.) are compound requirements, intuitive feel 100 times/S speed is not low, With the principle of PWM to control the flow of fluid in theory also what each question, In the electromagnetic valve can meet the requirements under the premise of experiment to grope for slowly, some Suggestions are as follows: 1: a separate test on and off solenoid valve can be action, 2: reduce the speed, the 1 1 second to switch, 3: speed increases gradually, test the speed of the solenoid valve is the most ideal, 4: adjust the duty ratio, the test liquid flow rate, liquid flow rate to calculate the PWM control the proportion of relations, I wish you good luck
CodePudding user response:
Now you want to achieve function, life, has given the noise, 150 can also meet, also have a quiet valve,
CodePudding user response:
The building Lord you can put your choice of solenoid valve model, parameter tell you?