Rosemount flowmeter reception problems solution

Time:01-01

Rosemount flowmeter sensor structure is simple, the measuring tube has no moving parts, no obstacles to fluid flow throttling parts, so when the fluid flow through timing does not cause any additional pressure loss, is a very can save energy consumption of the instrument,
Generally after installation without maintenance under the premise of rosemount flowmeter can run normally for a long time, need maintenance and daily inspection, after receiving less than signal or the signal is too weak are small problems, the user can according to the following method operation step by step to solve the problem:
1. The first to confirm whether the pipe filled with fluid;
2. If the pipe is too close to the wall, can be in the Angle of the tilt sensor installed on pipe diameter, and haven't installed in a horizontal pipe diameter, should choose the Z method to install the probe;
3. Carefully choose rosemount flowmeter pipelines dense part and fully polished bright, daub is full of lotus root mixture installed probe;
4. Carefully in installed near the point of moving slowly each probe, find the strongest signal points, prevent because of pipe wall scaling or because local deformation is expected to lead to the ultrasonic beam reflected area and miss can receives the strong point of installation;
5. The wall scaling rosemount flowmeter serious metal pipe can use of ways to make scale parts fall off or crack, but note that this method can sometimes because of scale and gaps between the lining and the useless at ultrasonic transmission,